首页> 外文期刊>Radiation Protection Dosimetry >Mayak Worker Dosimetry System (MWDS-2013): Phase I-Quality assurance of organ doses and excretion rates from internal exposures of Plutonium-239 for the Mayak Worker Cohort
【24h】

Mayak Worker Dosimetry System (MWDS-2013): Phase I-Quality assurance of organ doses and excretion rates from internal exposures of Plutonium-239 for the Mayak Worker Cohort

机译:Mayak工人剂量测定系统(MWDS-2013):I阶段-针对Mayak工人群体的internal239内部暴露对器官剂量和排泄率的质量保证

获取原文
获取原文并翻译 | 示例
           

摘要

The calculation of reliable and realistic doses for use in epidemiological studies for the quantification of risk from internal exposure to radioactive material is fundamental to the development of advice, guidance and regulations for the control and use of radioactive material. Thus, any programme of work carried out which requires the calculation of doses for use by epidemiologists ideally should contain a rigorous program of quality assurance (QA). This paper describes the initial QA (Phase I) implemented by Public Health England (PHE) and the Southern Urals Biophysics Institute (SUBI) as part of the work programme on internal dosimetry in the Joint Coordinating Committee for Radiation Effects Research Project 2.4 for the 2013 Mayak Worker Dosimetry System. SUBI designed and implemented new software (PANDORA) to include the latest Mayak Worker Dosimetry System and to calculate organ burdens, urinary excretion rates, intakes and absorbed doses, while PHE modified their commercially available IMBA Professional Plus software package. Comparisons of output from the two codes for the Mayak Worker Dosimetry System 2013 showed calculated values of absorbed doses, intakes, organ burdens and urinary excretion agreed to within 1%. The 1% discrepancy can be explained by the approximation used in IMBA to speed up dose calculations.
机译:流行病学研究中用于量化内部暴露于放射性物质的风险的可靠和实际剂量的计算,对于制定控制和使用放射性物质的建议,指南和法规至关重要。因此,理想情况下,任何需要计算流行病学家使用剂量的工作计划都应包含严格的质量保证(QA)计划。本文描述了由英国公共卫生(PHE)和南部乌拉尔生物物理研究所(SUBI)实施的初始质量保证(第一阶段),该研究是2013年辐射效应研究项目2.4联合协调委员会内部剂量学工作计划的一部分。 Mayak工人剂量测定系统。 SUBI设计并实施了新软件(PANDORA),以包括最新的Mayak工人剂量测定系统,并计算器官负担,尿排泄率,摄入量和吸收剂量,而PHE则修改了其市售的IMBA Professional Plus软件包。对Mayak工人剂量系统2013的两个代码的输出进行比较,显示吸收剂量,摄入量,器官负担和尿排泄的计算值均在1%以内。 1%的差异可以通过IMBA中用于加快剂量计算的近似值来解释。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2017年第2期|166-181|共16页
  • 作者单位

    Department of Toxicology, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, United Kingdom;

    Global Dosimetry, Didcot, Oxon, United Kingdom;

    Southern Urals Biophysics Institute (SUBI), Ozersk, Russian Federation;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号