The aim of this study was to propose first established diagnostic reference levels (DRLs) in computed tomography (CT) for adults, based on volume-averaged CTDI and dose length product (DLP) metrics in Yazd Province. Materials and Methods: Six multislice CT scanners located at diverse areas of Yazd Province and seven common procedures were selected for the present study. For each procedure, at least twenty patients 18 years and older were sampled at each institution. For each patient, dose report data and scan parameters as well as patient's information were abstracted from picture archiving and communication system. Results: Proposed DRLs in terms of computed tomography dose index (mGy) and DLP (mGy.cm) were as follows: brain (42,527), sinus (25,220), neck (14,264), abdomen-pelvis (11, 295), routine chest (8,247), CT pulmonary angiogram (32,261) and chest HRCT (11, 455), respectively, slightly lower compared to other investigations. Conclusion: The proposed DRLs in this study should be considered as the local DRLs for the seven most common adult CT examinations in Yazd province so as to optimize the patient dose while maintaining acceptable image quality for the clinical task.
机译:本研究的目的是根据亚兹德省的体积平均的CTDI和剂量长度产品(DLP)指标,提出第一次建立了计算断层扫描(CT)的诊断参考水平(DRL)。材料和方法:六个多层CT扫描仪位于亚兹德省各种地区,为本研究选择了七个常见程序。对于每种程序,每次机构都有18岁及以上的患者至少20名患者。对于每位患者,从图片归档和通信系统中抽象了剂量报告数据和扫描参数以及患者的信息。结果:在计算断层摄影剂量指数(MGY)和DLP(MGY.cm)方面提出了DRL,如下:脑(42,527),窦(25,220),颈部(14,264),腹部 - 骨盆(11,295),常规胸部(8,247),CT肺血管造影(32,261)和胸部HRCT(11,455),与其他研究相比略低。结论:本研究的拟议DRL应被视为亚兹德省七个最常见的成人CT考试的本地DRL,以优化患者剂量,同时保持临床任务的可接受的图像质量。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2020年第2期|222-231|共10页
  • 作者单位

    Medical Physics Department School of Medicine Shahid Sadoughi University of Medical Sciences and Health Services Yazd Yazd Province Iran;

    Medical Physics Department School of Medicine Shahid Sadoughi University of Medical Sciences and Health Services Yazd Yazd Province Iran;

    Medical Physics Department School of Medicine Shahid Sadoughi University of Medical Sciences and Health Services Yazd Yazd Province Iran;

    Medical Physics Department School of Medicine Shahid Sadoughi University of Medical Sciences and Health Services Yazd Yazd Province Iran;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号