The purpose of the article is to evaluate the annual effective dose for 80 women divided into two samples; one sample located in the former uranium Baita-Stei area, hereinafter referred to as case sample, respectively for a control sample, located in the same county, but exposed in most cases to indoor radon activity concentrations 300 Bqm(-3). In this regard, the homemade 'RaThoGamma' kit was used, which contained two thermoluminescent dosimeters, a CR-39 track detector (RSKS) for indoor radon activity concentration, two CR-39 track detectors (Radtrak(2)(R)/Radtrak(2T)(R)) for radon and thoron activity concentrations as well as Direct Radon Progeny Sensors/Direct Thoron Progeny Sensors for measuring time-averaged radon and thoron progenies concentrations. In addition, a total of 80 water samples were collected in order to evaluate the ingestion dose due to radon and radium activity concentrations in drinking water. The maximum total annual effective dose in the control sample was 14.1 mSv, while in the case sample the maximum annual effective dose was 60.5 mSv. This difference is mainly due to radon progenies inhalation. Other pathways did not show a statistically significant difference between the two samples, showing a minor contribution to the annual effective dose.
机译:本文的目的是评估80名妇女分为两种样品的年度有效剂量;位于前铀段 - Stei区域的一个样品,下文中,分别用于位于同一县的对照样品,但在大多数情况下暴露于室内氡活性浓度<300 bqm(-3)。在这方面,使用了自制的'rathogamma'套件,其中包含两个热辐发光剂量计,CR-39轨道检测器(RSK),用于室内氡活动浓度,两个CR-39轨道检测器(Radtrak(2)(R)/ Radtrak (2T)(r))用于氡和钍运动活性浓度以及用于测量时间平均氡和钍后代浓度的直接氡生成传感器/直接钍后代传感器。此外,收集总共80个水样,以评估由于氡和镭率浓度为饮用水中的摄取剂量。对照样品中的最大年度有效剂量为14.1msV,而在案例样本中,最大年度有效剂量为60.5msV。这种差异主要是由于氡后代吸入。其他途径在两个样品之间没有显示出统计学上的差异,对年度有效剂量显示出微小的贡献。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2019年第1期|7-16|共10页
  • 作者单位

    Babes Bolyai Univ Fac Environm Sci & Engn Constantin Cosma Radon Lab Cluj Napoca Romania;

    Babes Bolyai Univ Fac Environm Sci & Engn Constantin Cosma Radon Lab Cluj Napoca Romania;

    Babes Bolyai Univ Fac Environm Sci & Engn Constantin Cosma Radon Lab Cluj Napoca Romania;

    BARC Radiol Phys & Advisory Div Mumbai Maharashtra India;

    BARC Radiol Phys & Advisory Div Mumbai Maharashtra India;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号