The response of albedo dosemeters depends on the energy and angle of the incident neutron radiation. For their use as personal dosemeters, a field-calibration factor has to be applied. The presently used single sphere method for field calibration can be extended and optimised by putting five albedo dosemeters on the surface of a polyethylene sphere and two TL cards in the centre. To investigate the potential of this extension, reference measurements and Monte Carlo calculations were performed and the fluence response of the detectors at different positions on and within the sphere was determined. Calculated response functions demonstrate that information on the energy and directional distribution of neutron fluence can be extracted with this simple set-up for unknown neutron fields.
机译:反照剂量计的响应取决于入射中子辐射的能量和角度。为了用作个人剂量计,必须应用现场校准系数。通过在聚乙烯球表面放置五个反照率剂量计,在中心放置两个TL卡,可以扩展和优化当前使用的用于现场校准的单球方法。为了研究这种扩展的潜力,进行了参考测量和蒙特卡洛计算,并确定了球体上和球体内不同位置的探测器的注量响应。计算的响应函数表明,可以通过这种简单的设置来提取未知中子场的有关中子注量能量和方向分布的信息。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2018年第4期|422-426|共5页
  • 作者单位

    Phys Tech Bundesanstalt, Bundesallee 100, D-38106 Braunschweig, Germany;

    Phys Tech Bundesanstalt, Bundesallee 100, D-38106 Braunschweig, Germany;

    Helmholtz Zentrum Munchen AWST, Auswertungsstelle Strahlendosimeter, Otto Hahn Ring 6, D-81739 Munich, Germany;

    Phys Tech Bundesanstalt, Bundesallee 100, D-38106 Braunschweig, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号