Study on the quality assurance of diagnostic X-ray machines and assessment of the absorbed dose to patients

机译:诊断X射线机的质量保证和对患者吸收剂量的评估研究

获取原文
获取原文并翻译 | 示例
           

摘要

Radiation exposure and image quality in X-ray diagnostic radiology provide a clear understanding of the relationship between the radiation dose delivered to a patient and image quality in optimizing medical diagnostic radiology. Because a certain amount of radiation is unavoidably delivered to patients, this should be as low as reasonably achievable. Several X-ray diagnostic machines were used at different medical diagnostic centers in Egypt for studying the beam quality and the dose delivered to the patient. This article studies the factors affecting the beam quality, such as the kilo-volt peak (kVp), exposure time (mSc), tube current (mAs) and the absorbed dose in (μGy) for different examinations. The maximum absorbed dose measured per mAs was 594±239 and 12.5±3.7 μGy for the abdomen and the chest, respectively, while the absorbed dose at the elbow was 18±6 μGy, which was the minimum dose recorded. The compound and expanded uncertainties accompanying these measurements were 4±0.35% and 8±0.7%, respectively. The measurements were done through quality control tests as acceptance procedures.View full textDownload full textKeywordsdiagnostic X-ray, dose to patient, quality assuranceRelated var addthis_config = { ui_cobrand: "Taylor & Francis Online", services_compact: "citeulike,netvibes,twitter,technorati,delicious,linkedin,facebook,stumbleupon,digg,google,more", pubid: "ra-4dff56cd6bb1830b" }; Add to shortlist Link Permalink http://dx.doi.org/10.1080/10420150.2011.559238
机译:X射线诊断放射学中的放射线照射和图像质量使人们清楚了解了输送给患者的放射剂量与优化医学诊断放射学中的图像质量之间的关系。由于一定量的辐射不可避免地传递给患者,因此应尽可能合理地降低辐射量。埃及的不同医疗诊断中心使用了几台X射线诊断机来研究光束质量和输送给患者的剂量。本文研究影响光束质量的因素,例如千伏峰(kVp),曝光时间(mSc),管电流(mAs)和吸收剂量(μGy),以进行不同的检查。每mAs测量的最大吸收剂量分别为腹部和胸部的594±239和12.5±3.7μGy,而在肘部的吸收剂量为18±6μGy,这是记录的最小剂量。伴随这些测量的化合物和扩展的不确定性分别为4±0.35%和8±0.7%。测量是通过质量控制测试作为验收程序进行的。查看全文下载全文关键词诊断X射线,对患者的剂量,质量保证相关变量add add_id ,delicious,linkedin,facebook,stumbleupon,digg,google,more“,发布编号:” ra-4dff56cd6bb1830b“};添加到候选列表链接永久链接http://dx.doi.org/10.1080/10420150.2011.559238

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号