首页> 外文期刊>日本建築学会计画論文集 >CHARACTERISTICS OF CONVECTIVE HEAT TRANSFER COEFFICIENT ON BUILDING ARRAY MODEL BY WIND TUNNEL EXPERIMENT
【24h】

CHARACTERISTICS OF CONVECTIVE HEAT TRANSFER COEFFICIENT ON BUILDING ARRAY MODEL BY WIND TUNNEL EXPERIMENT

机译:风洞实验的建筑阵列模型对流换热系数特征

获取原文
获取原文并翻译 | 示例

摘要

Aiming to know characteristics of heat transfer coefficient from urban surface to upper atmosphere, experiments were carried out by using a building array model set in a boundary layer wind tunnel. The results show that both of forced and natural convections influence heat transfer coefficient.Effect of forced convention upon heat transfer coefficient is remarkable more thna that of natural convection. Composite expressions of Reynolds number Re and Grashof number Gr for Nusselt number Nu have been obtained for each surface; building and ground. These results are applied for the angle of Re 3.0x10~3 to 2.6x10~4 to 4.7x10~5.
机译:为了了解从城市表面到高层大气的热传递系数的特征,通过在边界层风洞中设置的建筑物阵列模型进行了实验。结果表明,强制对流和自然对流都会影响传热系数。强制常规对传热系数的影响比自然对流更明显。得到了每个表面的雷诺数Re和格拉索夫数Gr对努塞尔数Nu的复合表达式。建筑和地面。这些结果适用于Re 3.0x10〜3到2.6x10〜4到4.7x10〜5的角度。