Fractogaphy Of Beam-To-Column Welded Connections By Full Scale Shaking Table Test

机译:梁到柱焊接连接的断口形像的全尺寸振动台试验

获取原文
获取原文并翻译 | 示例

摘要

Full scale shaking table tests of beam-to-column welded connections were conducted under loading simulated Hanshin-Awaji earthquake at room temperature. In parallel to this, Charpy impact tests were also carried out. Fracture surface of large beam-to-column welded connections and small Charpy impact specimens were observed by a scaning electron microscope (SEM). The main conclusions obtained are as follows. SEM fractography showed that cleavage was observed in large specimens fractured at room temperature. This confirmed that steel structure components were brittle
机译:在室温模拟汉神-淡路地震荷载作用下,进行了梁柱焊接连接的全尺寸振动台试验。与此同时,还进行了夏比冲击试验。通过扫描电子显微镜(SEM)观察了大的梁对柱焊接连接的断裂表面和小的夏比冲击试样。得出的主要结论如下。 SEM断层扫描显示在室温下破裂的大样品中观察到了分裂。这证实了钢结构部件是脆性的