首页> 外文期刊>日本建築学会環境系論文集 >実大実験建物を用いたALCの床蓄熱特性に関する研究
【24h】

実大実験建物を用いたALCの床蓄熱特性に関する研究

机译:利用大型实验楼研究ALC的地板储热特性

获取原文
获取原文并翻译 | 示例
       

摘要

建材として幅広く使用されているものの熱挙動に関する検討事例rnが少ないALCに関して、室内気候や床蓄熱特性を明らかにするためrnに、床及び天井材をALC、合板、RCで構成した3つの実験室からなrnる実大実験建物を用いた実測およびシミュレーションによる検討をrn行った。%The thermal storage characteristics of autoclaved aerated concrete (AAC) was investigated by experimental measurements and simulations with three mutually separated rooms having AAC, plywood (PW), and reinforced concrete (RC). The comparison with the experimental results and the simulation results showed that the indoor thermal behavior of AAC room changed depending on the water content by weight of AAC panels. In the case of the AAC panels in an air-dried state, the room temperature and the floor surface temperature in the AAC room were generally intermediate between those of PW and RC rooms. Also, the AAC room's cooling load with intermittent air conditioning was intermediate between that of the other two rooms.
机译:ALC的三个示例,它们被广泛用作建筑材料,其中地板和天花板材料由ALC,胶合板和RC组成,目的是阐明ALC的室内气候和地板储热特性,其中很少我们使用实际测量和模拟进行了研究,并使用了完整的实验大楼。通过对三个相互独立的AAC,胶合板(PW)和钢筋混凝土(RC)的房间进行实验测量和模拟,研究了高压灭菌加气混凝土(AAC)的储热特性。与实验结果和模拟结果的比较表明AAC室的室内热行为随AAC板重量的含水量而变化.AAC板处于风干状态时,AAC室的室温和地板表面温度通常介于PW和RC房间.AAC房间的空调负荷是间歇性的,介于其他两个房间之间。