首页> 外文期刊>日本建築学会環境系論文集 >6m採熱管を使った地中熱利用の実験: 浅深度地中熱利用の研究(その2)
【24h】

6m採熱管を使った地中熱利用の実験: 浅深度地中熱利用の研究(その2)

机译:使用6m集热管进行地热利用的实验:浅层地热利用的研究(第2部分)

获取原文
获取原文并翻译 | 示例
       

摘要

The authors examined possibility of underground thermal energy use by using ground heat exchanger as short as 6m, from the viewpoint of temperature of ground, in study of underground thermal energy use from shallow underground (Part 1).It was found that the results, higher possibility of practicality of 6m ground heat exchanger in many areas including Hokkaido, in the same way as a oonventional ground heat exchanger 100m. In response to this, we carried out a field test by repeating measurement of short time underground thermal quantity and decreasing quantity of heat due to long-term operation. As a result it was confirmed, underground thermal energy use by 6m ground heat exchanger can be available to residential heating and cooling and decreasing quantity of heat after long term operation of 6 months is 51%.%今回行なった短時間測定法の推計によれば、@1,000〜1,800のピッチの採熱管配置で、運転から2か月間程度は6m採熱管も従来の100m採熱管の一般的採熱量とされる33〜45W/mと同程度以上の量の採熱が可能であるが、6か月程度の運転では約半分程度となることが判った。
机译:作者从地面温度的角度研究了浅埋地下地下热能利用的研究(第1部分),从地面温度的角度出发,探讨了使用地面热交换器短至6m进行地下热能利用的可能性(结果1)。在北海道等许多地区安装6m地面热交换器的可能性与常规地面热交换器100m相同。响应于此,我们通过重复测量短期地下热量并减少由于长期运行而产生的热量来进行现场测试。结果证实,6m地面换热器的地下热能可用于住宅供暖和制冷,并且经过6个月的长期运行后,热量的减少率为51%。 1,000,@ 1,000〜1,800のピッチの采热管配置で,运転から2か月间程度は6m采热管も従来の100m采热管の一般的采取とと33〜45W / mと同程度以上の量の采热が可能であるが,6か月程度の运転では约半分程度となることが判った。