Due to past several earthquakes, damage of elevators, especially in rope, were reported. It is quite important to maintain the function of an elevator for rescue activity after a severe earthquake. This study clarifies the correlation between vibration of a main rope of an elevator and the characteristics of a building (stiffness and damping factor). Influence of the setting position of a driving machine is also investigated. A model of a thirty-story building with elevator system is analyzed on vibration modes and dynamics responses to several seismic ground motions. It is shown that two-elevator system, which sets a transfer floor in the middle height of a building, can reduce the response of a main rope, and that increased damping factor can also reduce the response.%本研究では,30階建物を想定した建物・エレベーター連成系モデ ルを用い,固有値解析ならびに時刻歴応答解析により,建物の振動 特性とエレベーターのメインロープの地震応答の関係を分析した. 建物の振動特性(剛性,減衰)と巻上機の設置場所が異なるときの, 刺激関数における建物の質点位置とロープの質点位置の差βΔuと, 建物とロープ間の相対変位に着目して比較検討を行い,以下の知見 を得た.
机译:由于过去的几次地震,报告了电梯的损坏,特别是绳索的损坏。在发生严重地震后,保持电梯的功能对于救援活动非常重要。这项研究阐明了电梯主绳索的振动之间的相关性。并研究了驱动器的设置位置的影响。分析了一座有电梯系统的30层建筑物的模型,该模型对几种地震地震动的振动模式和动力响应进行了分析。研究表明,将两层电梯系统设置在建筑物中间高度的转换层可以降低主绳索的响应,而增加的阻尼系数也可以降低响应。%在此研究中,30层使用特征为建筑物的建筑物-电梯耦合模型,通过特征值分析和时程响应分析,分析了建筑物的振动特性与电梯主绳索的地震响应之间的关系。着眼于建筑物的振动特性(刚度,阻尼)与曳引机的安装位置不同时,刺激函数中建筑物质量位置与绳索质量位置之间的差βΔu,以及建筑物与绳索之间的相对位移。我们进行了一项研究,得出以下发现。