The experiments of post-installed adhesive rebar systems were taken in focusing on bond failure during the fire condition. The bond strengths have different performances depending on kinds of injection. Epoxy type decreased to about 1/10 in about 280°C, Urethane type decreased about 1/5 in about 200°C, and Inorganic type reduced about 1/3 in about 270°C. The test results are close to the prediction process for Epoxy while the two other resins fluctuated widely. The heating then loading test can be used as a method for predicting the bond strength of loading then heating test in the range of temperature from 50°C to 100°C.
机译:安装后粘合钢筋系统的实验是在火灾条件下关注粘合失效。粘合强度取决于注射种类的性能不同。环氧型在约280℃下减少至约1/10,氨基甲酸酯型约为约200℃,约200℃,无机型在约270℃下减少约1/3。测试结果接近环氧树脂的预测过程,而另外两种树脂很大。加热然后加载试验可用作预测负载粘合强度的方法,然后在温度范围为50℃至100℃的温度范围内加热试验。