摘要

1. FTIR testing showed no difference organically on the surface of the dendrites from the coated reference area. No root cause for the failure could be determined by this analytical method for dendrite growth. 2. SEM and optical imaging showed the dendrite growth was on top of the coating and that the coating did not completely cover the solder mound, leaving the exposed metal to react within the environmental conditions. Optical imaging with UV light showed the exposed metallization of the solder domes was not covered by conformal coating. No root cause for the failure could be determined by this analytical method for dendrite growth, but it does show there is an open path for condensate to bridge pads. 3. EDS analysis showed the dendrites are comprised of tin, carbon and oxygen. There was not enough concentration to detect chlorine or sulfur elements. No root cause for the failure could be determined by this analytical method for dendrite growth.
机译:1. FTIR测试表明,与涂覆的参考区域相比,树突的表面没有有机差异。用这种分析方法无法确定枝晶生长的根本原因。 2. SEM和光学成像显示枝晶生长在涂层顶部,并且涂层没有完全覆盖焊锡堆,使裸露的金属在环境条件下发生反应。用紫外光进行的光学成像表明,焊锡穹顶的裸露金属层没有被保形涂层覆盖。用这种分析方法无法确定枝晶生长的根本原因,但它确实表明凝结水有可能通向桥垫。 3. EDS分析表明,树枝状晶体由锡,碳和氧组成。浓度不足以检测氯或硫元素。用这种分析方法无法确定枝晶生长的根本原因。