The problem of imbalance detection in a three-phase power system using a phasor measurement unit (PMU) is considered. A general model for the zero, positive, and negative sequences from a PMU measurement at off-nominal frequencies is presented and a hypothesis testing framework is formulated. The new formulation takes into account the fact that minor degree of imbalance in the system is acceptable and does not indicate subsequent interruptions, failures, or degradation of physical components. A generalized likelihood ratio test (GLRT) is developed and shown to be a function of the negative-sequence phasor estimator and the acceptable level of imbalances for nominal system operations. As a by-product to the proposed detection method, a constrained estimation of the positive and negative phasors and the frequency deviation is obtained for both balanced and unbalanced situations. The theoretical and numerical performance analyses show improved performance over benchmark techniques and robustness to the presence of additional harmonics.
机译:考虑了使用相量测量单元(PMU)的三相电力系统中不平衡检测的问题。提出了在标称频率之外的PMU测量中零序,正序和负序的通用模型,并制定了假设检验框架。新的公式考虑到了这样的事实,即系统中较小程度的不平衡是可以接受的,并且不表示随后的物理组件中断,故障或降级。开发了广义似然比检验(GLRT),并证明它是负序相量估计器和名义系统运行可接受的不平衡水平的函数。作为所提出的检测方法的副产品,在平衡和不平衡情况下都获得了对正相量和负相量以及频率偏差的约束估计。理论和数值性能分析表明,与基准技术相比,性能得到了改善,并且对于存在其他谐波也具有鲁棒性。