首页> 外文期刊>IEEE Transactions on Power Systems >A voltage drop-based approach to include cold load pickup in design of distribution systems
【24h】

A voltage drop-based approach to include cold load pickup in design of distribution systems

机译:基于电压降的方法,在配电系统的设计中包括了冷负载拾取

获取原文
获取原文并翻译 | 示例
           

摘要

In distribution systems with large residential load, thermostatically controlled devices contribute major portion of total load. Restoration of such systems after prolonged interruption may create a load significantly higher than the normal load. This condition is called cold load pickup (CLPU). The enduring component of CLPU may cause severe voltage drops along the feeders and transformer heating, thus making the system restoration difficult. This paper discusses an approach to include restoration under CPLU conditions in distribution system planning and expansion. The approach can be applied to determine the most optimal transformer size and feeder sizes while ensuring the minimal restoration time and acceptable voltages and transformer heating during CLPU conditions. The aim is to develop a tool that can be used in conjunction with the overall distribution system design to ensure quality power even in emergency conditions while minimizing the cost.
机译:在居民负荷较大的配电系统中,恒温控制设备占总负荷的大部分。长时间中断后恢复此类系统可能会产生明显高于正常负载的负载。这种情况称为冷负载拾取(CLPU)。 CLPU的持久组件可能会导致沿馈线的严重电压降以及变压器发热,从而使系统恢复变得困难。本文讨论了一种在CPLU条件下将恢复包括在配电系统规划和扩展中的方法。该方法可用于确定最佳的变压器尺寸和馈线尺寸,同时确保最短的恢复时间以及CLPU条件下可接受的电压和变压器发热。目的是开发一种可与整个配电系统设计结合使用的工具,以确保即使在紧急情况下也能确保高质量的电源,同时将成本降至最低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号