首页> 外文期刊>IEEE Transactions on Power Delivery >Alternative method for evaluation of damping circuit losses in HVDC thyristor valves
【24h】

Alternative method for evaluation of damping circuit losses in HVDC thyristor valves

机译:评估HVDC晶闸管阀阻尼电路损耗的替代方法

获取原文
获取原文并翻译 | 示例
           

摘要

An accurate method for calculating the damping circuit losses in HVDC converter systems is proposed. It is based on an equivalent circuit representation of the converter system during each interval of conduction over a power frequency period. The results are compared with the results obtained by the approximate formula proposed by J.D. Ainsworth and with the results obtained using the second-order approximate model to simulate valve voltage oscillations during each commutation. The variation of damping circuit loss with bridge operating parameters and with the damping parameters is also analyzed.
机译:提出了一种计算直流输电系统阻尼电路损耗的精确方法。它基于在电源频率周期内每个导通间隔内转换器系统的等效电路表示。将结果与通过J.D. Ainsworth提出的近似公式获得的结果进行比较,并与使用二阶近似模型获得的结果进行比较,以模拟每次换向期间的阀电压振荡。还分析了阻尼电路损耗随电桥操作参数和阻尼参数的变化。