An on-line fault section detection system, which continuously monitors a 275-kV cross-linked polyethylene-insulated underground transmission line and instantaneously determines the section of fault at a ground fault, was developed. In the case of a ground fault, the system detects the fault current which flows from the power source to the point of ground fault and determines the fault section from the magnitude and phase information of the fault current. Optical magnetic field sensors based on the Faraday effect are used for detection of fault current, and optical fibers are used for signal transmission eliminating effects of electromagnetic induction due to a large ground fault current (5000-50000 A) or switching surges on signal transmission lines. The distance between an optical magnetic field sensor and the fault section detector/indicator can be as long as 10 km without the use of any repeaters.
机译:开发了一种在线断面检测系统,该系统可以连续监视275 kV交联的聚乙烯绝缘地下输电线路,并即时确定接地故障的断面。在发生接地故障的情况下,系统会检测从电源流向接地故障点的故障电流,并根据故障电流的大小和相位信息确定故障区域。基于法拉第效应的光磁场传感器用于检测故障电流,并且光纤用于信号传输,以消除由于大的接地故障电流(5000-50000 A)或信号传输线上的开关浪涌而引起的电磁感应效应。在不使用任何中继器的情况下,光磁场传感器与故障区域检测器/指示器之间的距离可以长达10 km。