The work reported in this paper can be grouped into threencategories: empirical investigations; analytical studies; and computernsimulations. The studies have identified the causes of high transientnovervoltages which are produced when switching high voltage shuntnreactors. Laboratory and site testing have shown that multiplenreignition is the most likely cause of the high overvoltages. Circuitnanalysis has been carried out to identify the conditions which lead tonmultiple reignitions. A computer model has been developed to allow thenlikelihood of multiple reignitions occurring to be assessed
机译:本文报告的工作可以分为三类:实证研究;分析研究;和计算机模拟。研究已经确定了切换高压并联电抗器时产生高瞬态过电压的原因。实验室和现场测试表明,多重点火是高过电压的最可能原因。已经进行了电路分析来确定导致多次点火的条件。已经开发了一种计算机模型,可以评估发生多次点火的可能性