Analysis and characterization of the shunt reactor switching over-voltages interrupted by SF6 circuit breakers with chopping current

机译:带斩波电流的SF6断路器中断的并联电抗器开关过电压的分析和表征

获取原文

摘要

Shunt reactor interruption by circuit breakers may produce current chopping and cause severe overvoltages. The four-legged reactor interrupting transients are elucidated with equivalent circuit analysis, and the mechanism of beat frequency oscillation is also characterized, further, a 3-D portfolio of the beat frequency, specifically regarding shunt reactor interrupting with a short line distance is given to describe the variation trend versus the shunt reactor's parameters. Based on the available parameters from an installed 750kV transmission line in China, simulations of the four-legged reactor interruption process are carried out with adoption of an appropriate arc model for SF6 circuit breakers, and the scenario of the switching overvoltages is presented for the shunt reactor interrupting. The research results present useful reference for future construction and operation of the EHV and UHV transmission lines.
机译:断路器对并联电抗器的干扰可能会产生电流斩波并导致严重的过电压。通过等效电路分析阐明了四足电抗器的中断瞬变,并描述了拍频振荡的机理,此外,还给出了拍频的3-D组合,特别是关于短距离的并联电抗器的中断。描述变化趋势与并联电抗器参数的关系。根据中国已安装的750kV输电线路的可用参数,采用适用于SF6断路器的电弧模型对四足电抗器中断过程进行了仿真,并给出了分流开关过电压的情况反应堆中断。研究结果为超高压和特高压输电线路的未来建设和运行提供了有益的参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号