首页> 外文期刊>IEEE Transactions on Power Delivery >Chaos-based modeling of DC arc furnaces for power quality issues
【24h】

Chaos-based modeling of DC arc furnaces for power quality issues

机译:直流电弧炉基于混沌的电能质量问题建模

获取原文
获取原文并翻译 | 示例

摘要

DC arc furnaces are more and more applied in large industrial systems and represent one of the major sources of perturbations for the feeding system. This paper deals with the problem of the dc arc modeling using three well-known chaotic attractors (RÖssler, Chua, and Lorenz attractors). A new tuning procedure is adopted to determine the most adequate parameters of the attractors to model the dc arc furnace. Waveform distortions and voltage fluctuations indexes are calculated from the simulation results of a whole existing plant and compared with measured data. The proposed models of dc arc furnace can be used to assess the impact in terms of power quality of the dc arc furnace when planning new plants or evaluating the performances of compensating devices.
机译:直流电弧炉越来越多地应用在大型工业系统中,并成为进料系统扰动的主要来源之一。本文使用三个著名的混沌吸引子(Rössler,Chua和Lorenz吸引子)解决了直流电弧建模的问题。采用新的调整程序来确定吸引器的最合适参数,以对直流电弧炉进行建模。波形失真和电压波动指标是根据整个现有工厂的模拟结果计算得出的,并与测量数据进行比较。在计划新工厂或评估补偿设备的性能时,所建议的直流电弧炉模型可用于评估直流电弧炉电能质量的影响。