...
首页> 外文期刊>IEEE Transactions on Power Delivery >A Practical Implementation of Statistical Principles to Dimension AC Line Insulators With Respect to Contaminated Conditions
【24h】

A Practical Implementation of Statistical Principles to Dimension AC Line Insulators With Respect to Contaminated Conditions

机译:统计原理在污染条件下确定交流线路绝缘子尺寸的实用方法

获取原文
获取原文并翻译 | 示例
           

摘要

A practical and simplified implementation is presented for the dimensioning of insulators with respect to contamination conditions based on statistical analysis. This simplified statistical method entails the selection of a minimum insulator withstand severity relative to the site contamination severity by making use of a coordination factor. Evidence is presented to show that the proposed dimensioning procedure agrees well with present IEC creepage distance requirements for disc overhead line insulators, based on a commonly used availability requirement and a realistic number of insulator strings on the line. Results from the contamination laboratory test can be used to verify the withstand characteristic of the selected insulators. This simplified method may be used for dimensioning overhead ac line insulation when there is insufficient statistical information available to warrant full risk analysis
机译:针对绝缘子的尺寸,根据统计分析提出了一种实用且简化的实现方案。这种简化的统计方法需要通过使用协调因子来选择相对于现场污染严重性的最小绝缘体承受严重性。证据表明,根据常用的可用性要求和生产线上的实际绝缘子串数,建议的尺寸确定程序与圆盘架空绝缘子的现行IEC爬电距离要求非常吻合。污染实验室测试的结果可用于验证所选绝缘子的耐受特性。当没有足够的统计信息来保证进行全面风险分析时,可以使用这种简化方法来确定架空交流线路绝缘的尺寸

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号