A new wide-area backup protection algorithm based on the fault component voltage distribution is proposed in this paper. It is helpful to overcome the problems of complex setting and maloperation under flow transfer of conventional backup protection. The measured values of fault component voltage and current at one terminal of the transmission line are applied to estimate the fault component voltage at the other terminal. Then, the fault element can be identified by the ratio between the measured values and the estimated values. In addition, the speed of fault element identification can be accelerated by a faulted area detection scheme. The proposed method has the advantage of easy setting and low requirement for synchronized wide-area data. The studies performed on the IEEE 39-bus system validate the proposed algorithm under various faults and flow transfer.
机译:提出了一种基于故障分量电压分布的广域备用保护算法。克服了传统后备保护在流量传递下设置复杂,操作不当的问题。传输线一端的故障分量电压和电流的测量值用于估计另一端的故障分量电压。然后,可以通过测量值和估计值之间的比率来识别故障元素。另外,通过故障区域检测方案可以加快故障元素识别的速度。所提出的方法具有易于设置和对同步广域数据的要求低的优点。在IEEE 39总线系统上进行的研究验证了该算法在各种故障和流量传递下的有效性。