This study was conducted to investigate heat generation in a landfill on a field scale, including the variation of temperatures. Data were collected at Stepanovice landfill in southwestern Czech Republic. Temperatures were determined over a monitoring period of 21 months. Mean annual value of the difference between outdoor temperature and temperature at a depth of 100 cm in the landfill body in 2012 amounted to 5.4 degrees C, and for the reporting period of 2013 it equailed 5.2 degrees C. No significant differences among measured temperatures were recorded at particular depths (50 cm, 75 cm, and 100 cm). Mean temperature at the surface of the landfill within the whole reporting period was 3.2 degrees C higher than ambient temperature (in the reporting period). This is explained due to the decomposition activity within the landfill site leading to the emission of warm gases. The results provide new information for the estimation of the selection of plant species suitable for reclamation, which have higher chances to tolerate the unfavorable conditions they would be exposed to a technically reclaimed landfill body.
机译:进行这项研究的目的是调查垃圾填埋场在田间产生的热量,包括温度的变化。数据是在捷克西南部的Stepanovice垃圾填埋场收集的。在21个月的监测期内确定温度。 2012年,垃圾掩埋场中室外温度与深度为100 cm的温度之间的年均平均值为5.4摄氏度,2013年的报告期间为5.2摄氏度。实测温度之间没有显着差异在特定深度(50厘米,75厘米和100厘米)。在整个报告期内,垃圾填埋场表面的平均温度比环境温度(报告期内)高3.2摄氏度。这是由于填埋场内部的分解活动导致了热气体的排放而解释的。结果为评估适合于垦殖的植物物种的选择提供了新的信息,这些物种具有较高的机会来忍受暴露于技术回收填埋场的不利条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号