From these tests, recommendations are possible on probe insertion depths in gas pipelines that may carry small amounts of liquid contaminants. A key observation is that samples from the straight-cut probe in the API Type I flow were repeatable. This suggests that the Type I gas-liquid flow patterns were stable and that the straight-cut probe can block some, but not all, of the mist from entering the sample. The Type I tests also showed that the local LVF due to mist in the gas core decreases toward the top of the pipe. Therefore, to minimize liquid ingestion from Type I flows, it is preferable to insert the probe tip to a depth above the center one-third of the pipe cross section.
机译:通过这些测试,可能会建议在可能携带少量液体污染物的气体管道中插入探头深度。一个关键的观察结果是,来自API Type I流程中直接探针的样品是可重复的。这表明I型气液流动模式是稳定的,并且直切探头可以阻止部分但不是全部的雾进入样品。 I型测试还显示,由于气芯中的薄雾导致的局部LVF朝着管道顶部减小。因此,为了使从I型流中摄入的液体最小化,最好将探头尖端插入到管道横截面中心三分之一以上的深度。