T.D. Williamson, Inc. (TDW) recently developed a new approach to seam assessments based on induction of magnetism using a "spiral" or "oblique" field, creating what is called a spiral magnetic flux leakage (SMFL) tool. As shown in Figure 2, this patent-pending spiral design provides complete pipe-wall inspection in a single, compact magnetizer rather than the two magnetizers required by TFI tools.
机译:T.D. Williamson,Inc.(TDW)最近开发了一种新的接缝评估方法,该方法基于使用“螺旋”或“倾斜”磁场的磁感应强度,创建了所谓的螺旋磁通量泄漏(SMFL)工具。如图2所示,该正在申请专利的螺旋设计可在单个紧凑的充磁机中提供完整的管壁检查,而不是TFI工具所需的两个充磁机。

著录项

  • 来源
    《Pipeline & Gas Journal》 |2011年第3期|p.42-44|共3页
  • 作者

    Chuck Harris;

  • 作者单位

    By Chuck Harris, T.D. Williamson, Inc.Author: Chuck Harris is the general manager of TDWs Western Hemisphere Pipeline Integrity Operation and based in Houston. Harris has IH years experience in the inline inspection industry. He started in data analysis in 1993, later migrating to technical sales. He joined TDW in 2003 in Applications Sales Support and held several sales roles prior to his current responsibility. Harris holds a bachelors degree in business from LeTourneau University.;