首页> 外文期刊>PCI Journal >Debonding strands as an anchorage zone crack control method for pretensioned concrete bulb-tee girders
【24h】

Debonding strands as an anchorage zone crack control method for pretensioned concrete bulb-tee girders

机译:剥离股线作为预张紧混凝土灯泡三梁的锚地裂缝控制方法

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

To meet bridge load demands efficiently, pretensioned concrete bulb-tee girders are heavily prestressed in most cases. Although the pretension force is transferred gradually to concrete near girder ends, tensile stresses developing in the anchorage zones can be large enough to create cracks in relatively thin girder webs. Deeper girders with larger prestressing forces tend to have more, longer, or wider cracks.~1 When end zones are not encased in concrete diaphragms, cracks may create concerns for corrosion. Tad-ros et al.~2 recommended repairing cracks between 0.012 and 0.050 in. (0.30 and 1.27 mm) in width and rejecting girders with cracks larger than 0.050 in. in width.
机译:为了高效地满足桥梁载荷需求,在大多数情况下,预张紧的混凝土灯泡三梁在大多数情况下大量预应力。尽管预张力逐渐转移到近梁末端的混凝土端部,但在锚固区中发育的拉伸应力可以足够大以在相对薄的梁腹板中产生裂缝。具有较大预应力力的更深的梁往往具有更多,更长或更宽的裂缝。〜1当端区没有被混凝土隔膜被封闭时,裂缝可能会对腐蚀产生担忧。 TAD-ROS等人。〜2推荐修复0.012和0.050英寸的裂缝,宽度和抑制梁,宽度大于0.050英寸。