首页> 外文期刊>Optics and Lasers in Engineering >Flexible calibration method for line-scan cameras using a stereo target with hollow stripes
【24h】

Flexible calibration method for line-scan cameras using a stereo target with hollow stripes

机译:使用带有空心条纹的立体声目​​标的线扫描相机的灵活校准方法

获取原文
获取原文并翻译 | 示例
       

摘要

With the advantages of ultrahigh resolution and acquisition rate, stereo line-scan sensors are gradually being developed for three-dimensional (3D) measurements. Calibration is crucial for line-scan cameras. However, viewing targets of line-scan cameras from different angles cause eccentricity errors. This paper presents a flexible calibration method for line-scan cameras to solve the eccentricity error problem. The calibration quality is improved by the accurate extraction of one-dimensional (1D) points on line-scan images, and the corresponding 3D points in space. Through the analysis of the eccentricity error in 1D image point extraction when utilizing targets with solid stripes, a stereo target with hollow stripes is designed. An algorithm is described to calculate the 3D points of intersection between the centerlines of hollow lines on the target and the viewing plane of the camera. A robust optimization is proposed to enhance the stability of parameter estimation. Experiments are performed to compare the re-projection error between the cross-ratio-based method and proposed method. A simulation is also performed to estimate the combined uncertainty. The comparative results of the experiments verify that the proposed method is accurate, low cost, and easy to implement.
机译:凭借超高分辨率和采集速率的优势,立体线扫描传感器正在逐步开发用于三维(3D)测量。校准对于线扫描相机至关重要。然而,从不同角度观看线扫描相机的目标会导致偏心误差。本文提出了一种用于线扫描相机的灵活校准方法,以解决偏心误差问题。通过精确提取线扫描图像上的一维(1D)点以及空间中相应的3D点,可以提高校准质量。通过分析利用带实条纹的目标时一维图像点提取中的偏心误差,设计了具有空心条纹的立体目标。描述了一种算法,用于计算目标上的空心线的中心线与相机的视线之间的3D相交点。提出了鲁棒性优化以增强参数估计的稳定性。进行了实验,以比较基于交叉比率的方法和提出的方法之间的重投影误差。还执行仿真以估计组合的不确定性。实验结果表明,该方法准确,成本低,易于实现。

著录项

  • 来源
    《Optics and Lasers in Engineering》 |2019年第2期|6-13|共8页
  • 作者单位

    Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China;

    Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China;

    Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China;

    Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China;

    Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China;

    Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Calibration; Line-scan camera; Hollow stripes; Eccentricity error; Flexibility;

    机译:校准;线扫描相机;空心条纹;偏心误差;柔韧性;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号