首页> 外文期刊>Nuclear Technology >HIGH-ENERGY COMPUTER TOMOGRAPHY MEASUREMENTS IN A MUSEUM AND ANALYSIS OF THE RADIOPROTECTION PROBLEM
【24h】

HIGH-ENERGY COMPUTER TOMOGRAPHY MEASUREMENTS IN A MUSEUM AND ANALYSIS OF THE RADIOPROTECTION PROBLEM

机译:博物馆中的高能计算机断层摄影测量和放射防护问题的分析

获取原文
获取原文并翻译 | 示例
       

摘要

In recent years there has been a growing demand from museums for computed tomography (CT) diagnostic measurements to be performed on famous artworks (sculptures and paintings) inside the museum itself in order to assess whether are they in good condition or need a restoration procedure. The problem of radiopro-tection becomes critical when the energy used in CT is high, as typically occurs in the case of CT measurements on sculptures, where linacs are used to produce the high-energy X-rays necessary to penetrate marble or metal. In this study we used Monte Carlo simulations in order to evaluate dose distribution inside a museum where a high-energy CT system is used for diagnostic measurements on a sculpture.
机译:近年来,博物馆对计算机断层扫描(CT)诊断测量的需求不断增长,这些测量要在博物馆内部的著名艺术品(雕塑和绘画)上进行,以评估它们是否状况良好或需要修复程序。当CT中使用的能量很高时,放射防护的问题就变得至关重要,就像在雕塑的CT测量中通常会发生的情况一样,其中使用直线加速器产生穿透大理石或金属的高能X射线。在这项研究中,我们使用蒙特卡洛模拟来评估博物馆内的剂量分布,在博物馆中,高能CT系统用于雕塑的诊断测量。

著录项

  • 来源
    《Nuclear Technology》 |2009年第1期|231-234|共4页
  • 作者单位

    University of Bologna and INFN Department of Physics, C. Betty Pichat 6-2, Bologna 40100, Italy;

    University of Bologna and INFN Department of Physics, C. Betty Pichat 6-2, Bologna 40100, Italy;

    University of Bologna and INFN Department of Physics, C. Betty Pichat 6-2, Bologna 40100, Italy;

    University of Bologna and INFN Department of Physics, C. Betty Pichat 6-2, Bologna 40100, Italy;

    University of Bologna and INFN Department of Physics, C. Betty Pichat 6-2, Bologna 40100, Italy;

    University of Bologna and INFN Department of Physics, C. Betty Pichat 6-2, Bologna 40100, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Monte Carlo; tomography; radioprotection;

    机译:蒙特卡洛;断层扫描放射防护;
  • 入库时间 2022-08-18 00:44:13

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号