首页> 外文期刊>Nuclear Technology >HIGH-PERFORMANCE DIFFERENTIAL PRESSURE MONITORING DEVICES USING PULSATING SENSORS FOR A SODIUM-COOLED FAST BREEDER REACTOR
【24h】

HIGH-PERFORMANCE DIFFERENTIAL PRESSURE MONITORING DEVICES USING PULSATING SENSORS FOR A SODIUM-COOLED FAST BREEDER REACTOR

机译:使用脉动传感器的高性能差压监测装置,用于钠冷快热堆反应器

获取原文
获取原文并翻译 | 示例
       

摘要

We present an unconventional but high-performance differential pressure (DP) monitoring instrument constructed using a new class of sensor, i.e., a pulsating sensor developed in-house. This instrument of unique design is of industrial grade, and it is specially made for online monitoring of pressure in the Prototype Fast Breeder Reactor (PFBR), located in Kalpakkam, India. It measures pressure in two different ranges—0 to 25 mbars (0 to 2.5 kPa) and 0 to 60 mbars (0 to 6.0 kPa)—using two specially designed capacitance-based robust probes made of stainless steel (Type 304L). The performance of this innovative instrument using both probes was thor- oughly investigated at ambient room temperature as well as at elevated temperatures (above 30℃ to 60℃) in order to assess its suitability for reactor application. The precision, sensitivity, response time, and lowest detection limit of measurement using this pulsating DP monitoring instrument are <0.01 mbars (0.001 kPa), 423 Hz/mbar (4230 Hz/kPa), ~5 s, and 0.07 mbars (0.007 kPa), respectively. The influence of temperature up to 60℃ on the measured parameters was found to be insignificant. A calibration technique has been evaluated to calibrate these pressure sensors.
机译:我们提出了一种非常规但高性能的压差(DP)监测仪器,该仪器使用新型传感器(即内部开发的脉动传感器)构造而成。这种具有独特设计的仪器是工业级的,是专为在线监测位于印度卡尔帕卡姆的原型快速增殖反应堆(PFBR)中的压力而制造的。它使用两个特别设计的基于电容的坚固耐用的不锈钢制成的探头(304L型),在两个不同的范围内测量压力-0至25 mbars(0至2.5 kPa)和0至60 mbars(0至6.0 kPa)。通过在室温和高温(30℃至60℃以上)下彻底研究了使用这两种探头的这种创新仪器的性能,以评估其在反应堆中的适用性。使用该脉动DP监测仪的精度,灵敏度,响应时间和最低检测限分别为<0.01 mbars(0.001 kPa),423 Hz / mbar(4230 Hz / kPa),〜5 s和0.07 mbars(0.007 kPa) ), 分别。发现最高温度为60℃对测量参数的影响不明显。已经评估了一种校准技术来校准这些压力传感器。

著录项

  • 来源
    《Nuclear Technology》 |2011年第1期|p.127-137|共11页
  • 作者单位

    Indira Gandhi Centre for Atomic Research, Real Time Systems Division, Innovative Instrumentation Section, Kalpakkam-603102, Tamil Nadu, India;

    Indira Gandhi Centre for Atomic Research, Real Time Systems Division, Innovative Instrumentation Section, Kalpakkam-603102, Tamil Nadu, India;

    Indira Gandhi Centre for Atomic Research, Real Time Systems Division, Innovative Instrumentation Section, Kalpakkam-603102, Tamil Nadu, India;

    Indira Gandhi Centre for Atomic Research, Real Time Systems Division, Innovative Instrumentation Section, Kalpakkam-603102, Tamil Nadu, India;

    Indira Gandhi Centre for Atomic Research, Real Time Systems Division, Innovative Instrumentation Section, Kalpakkam-603102, Tamil Nadu, India;

    Indira Gandhi Centre for Atomic Research, Real Time Systems Division, Innovative Instrumentation Section, Kalpakkam-603102, Tamil Nadu, India;

    Indira Gandhi Centre for Atomic Research, Real Time Systems Division, Innovative Instrumentation Section, Kalpakkam-603102, Tamil Nadu, India;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    differential pressure monitoring instrument; pulsating sensor; prototype fast breeder reactor;