首页> 外文期刊>Nuclear Technology >EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THE PASSIVE CONDENSATION COOLING TANK WATER LEVEL IN THE THERMAL PERFORMANCE OF THE PASSIVE AUXILIARY FEEDWATER SYSTEM
【24h】

EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THE PASSIVE CONDENSATION COOLING TANK WATER LEVEL IN THE THERMAL PERFORMANCE OF THE PASSIVE AUXILIARY FEEDWATER SYSTEM

机译:被动冷凝式给水系统热性能对被动冷凝式冷却水箱水位影响的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the Advanced Power Reactor Plus (APR +) and is designed to completely replace a conventional, active auxiliary feed-water system. With the aim of validating the cooling and operational performance of the PAFS, a separate effect test facility, the PAFS Condensing heat removal Assessment Loop (PASCAL), was constructed by simulating a single passive condensation heat exchanger (PCHX) tube submerged in the passive condensation cooling tank (PCCT) according to the volumetric scaling methodology. During heat removal of the PAFS, the pool water in the PCCT plays a role in the ultimate heat sink of a decay heat. In this study, the effect of the PCCT water level on the cooling performance of the PAFS was experimentally investigated with the PASCAL facility. Quasi-steady-state and PCCT level decrease test cases were sequentially performed by varying the steam generator heater power from 300 to 750 kW to investigate the thermal-hydraulic behavior during the decrease of the PCCT water level. From the experimental results, it was found that the decrease of the PCCT water level enhanced evaporative heat transfer at the outer wall of the PCHX tube by reducing the degree of subcooling around the PCHX. That induced an increase of the heat removal rate by the PCHX during the transient. Thus, it can be concluded that the current design of the PCHX in the PAFS has sufficient capacity to cool down the decay heat during the whole transient of the PCCT water level decrease.
机译:被动辅助给水系统(PAFS)是Advanced Power Reactor Plus(APR +)中采用的高级安全功能之一,旨在完全替代传统的主动辅助给水系统。为了验证PAFS的冷却和运行性能,通过模拟浸没在被动冷凝中的单个被动冷凝热交换器(PCHX)管,构造了一个单独的效果测试设备,即PAFS冷凝散热评估环路(PASCAL)。冷却水箱(PCCT)根据容积缩放方法。在去除PAFS的热量期间,PCCT中的池水在衰减热量的最终散热器中起作用。在这项研究中,使用PASCAL装置通过实验研究了PCCT水位对PAFS冷却性能的影响。通过将蒸汽发生器加热器的功率从300 kW更改为750 kW,依次执行准稳态和PCCT水位降低测试案例,以研究PCCT水位降低期间的热工行为。从实验结果中发现,PCCT水位的降低通过降低PCHX周围的过冷度而增强了PCHX管外壁的蒸发传热。在瞬态过程中,这导致了PCHX的散热率增加。因此,可以得出结论,在PCCT水位下降的整个瞬态过程中,PAFS中PCHX的当前设计具有足够的能力来冷却衰减热。

著录项

  • 来源
    《Nuclear Technology》 |2013年第3期|479-492|共14页
  • 作者单位

    Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division 1045 Daedeok-daero, Yuseong-gu, Daejeon, 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division 1045 Daedeok-daero, Yuseong-gu, Daejeon, 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division 1045 Daedeok-daero, Yuseong-gu, Daejeon, 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, Thermal Hydraulics Safety Research Division 1045 Daedeok-daero, Yuseong-gu, Daejeon, 305-353, Republic of Korea;

    Pusan National University, School of Mechanical Engineering, 30 Jangjeon-dong Geumjeong-gu, Busan, 609-735, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    passive auxiliary feedwater system; condensing heat removal assessment loop; passive condensation cooling tank;

    机译:被动辅助给水系统;冷凝散热评估回路;被动式冷凝水箱;
  • 入库时间 2022-08-18 00:43:16