首页> 外文期刊>Nuclear engineering and technology >SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR+ PASSIVE AUXILIARY FEEDWATER SYSTEM
【24h】

SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR+ PASSIVE AUXILIARY FEEDWATER SYSTEM

机译:APR +无源辅助给水系统冷却和运行性能验证的单独和整体效果测试

获取原文
获取原文并翻译 | 示例
       

摘要

The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+, which is intended to completely replace the conventional active auxiliary feedwater system. With an aim of validating the cooling and operational performance of PAFS, an experimental program is in progress at KAERI, which is composed of two kinds of tests; the separate effect test and the integral effect test. The separate effect test, PASCAL (PAFS Condensing Heat Removal Assessment Loop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in PAFS. A single, nearly-horizontal U-tube, whose dimensions are the same as the prototypic U-tube of the APR+ PAFS, is simulated in the PASCAL test. The PASCAL experimental result showed that the present design of PAFS satisfied the heat removal requirement for cooling down the reactor core during the anticipated accident transients. The integral effect test is in progress to confirm the operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. As the first integral effect test, an FLB (feedwater line break) accident was simulated for the APR+. From the integral effect test result, it could be concluded that the APR+ has the capability of coping with the hypothetical FLB accident by adopting PAFS and proper set-points of its operation.
机译:被动辅助给水系统(PAFS)是APR +中采用的高级安全功能之一,旨在完全替代传统的主动辅助给水系统。为了验证PAFS的冷却和运行性能,KAERI正在进行一项实验计划,该计划由两种测试组成:独立效果测试和整体效果测试。正在执行单独的效果测试PASCAL(PAFS冷凝热去除评估回路),以实验研究PAFS中的冷凝热传递和自然对流现象。在PASCAL测试中模拟了一个单一的近水平U形管,其尺寸与APR + PAFS的原型U形管相同。 PASCAL实验结果表明,PAFS的当前设计满足了在预期事故瞬变期间冷却反应堆堆芯的散热要求。正在进行整体效果测试,以确认PAFS的运行性能,以及使用ATLAS设施的反应堆冷却剂系统。作为第一个积分效应测试,模拟了APR +的FLB(给水管线中断)事故。从积分效应测试结果可以得出结论,APR +通过采用PAFS及其正确的设定值,能够应对假设的FLB事故。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号