Simultaneous indoor measurements of radon, thoron and equilibrium equivalent concentrations, by three different continuous radon monitors in real ambient conditions, were performed and compared during two weeks period. Radon concentrations varied from 153 Bqm~(-3) to 870 Bqm~(-3) with variations of thoron concentrations in the range (2.17-219) Bqm~(-3). Obtained arithmetic means of equilibrium equivalent radon and thoron concentrations were (130 ± 50) Bqm~(-3) and (23 ± 18) Bqm~(-3), respectively. The inter-comparison of active radon devices was focused on consistency of results between themselves and the influence of environmental conditions on the behavior of each detector system. The obtained statistically significant correlation between the results of used monitors, validates them for application in radon diagnostic measurements as the first step in radon remediation and dose assessment.
机译:在实际环境条件下进行氡,钍钍和平衡等效浓度的同时测量,在真实环境条件下进行三种不同的连续氡监测器,并在两周内进行比较。氡浓度从153 bqm〜(-3)到870 bqm〜(-3)不同,钍浓度在范围内(2.17-219)BQM〜(-3)。获得的平衡等效氡和钍浓度的算法分别为(130±50)BQM〜(-3)和(23±18)BQM〜(-3)。活性氡装置的相互比较专注于本身之间的结果和环境条件对每个探测器系统的行为的一致性。所获得的使用显示器的结果之间获得的统计学相关性,验证它们在氡诊断测量中应用作为氡修复和剂量评估的第一步。