One of the most measurable improvements in power reactor operations in recent years has been in the performance of fuel. Fuel pellets, cladding, and assembly hardware have become so dependable that the Institute of Nuclear Power Operations set an industrywide goal a few years ago of no fuel failures at a reactor in a year. For this reason, it was unusual for two fuel-related problems to be reported within four days. On September 12, Entergy informed the Nuclear Regulatory Commission that a cask of spent fuel from ANO-1 that was in the drying process was found to be out of specification because of the detection of krypton-85. On September 15, Dominion stated that during a refueling outage at North Anna-2, it was determined that two fuel pins in a removed fuel assembly had split, and an estimated 15 fuel pellets had been dislodged.
机译:近年来,动力堆运行中最可衡量的改进之一就是燃料的性能。燃料芯块,包壳和组装硬件变得如此可靠,以至于几年前核动力运行研究所设定了全行业目标,即一年内反应堆无燃料故障。因此,在四天内报告两个与燃料有关的问题是很不寻常的。 9月12日,Entergy通知核监管委员会,由于检测到85 85,发现一桶来自ANO-1的处于干燥过程中的乏燃料不合规格。 9月15日,多米尼克(Dominion)表示,在北安娜2号(North Anna-2)的一次加油中断期间,确定拆下的燃料组件中的两个燃料销已分开,并且估计有15个燃料团块被移出。