This report describes an S-band photoinjector with replaceable Cs_2Te photocathodes. The photoinjector is equipped with a cathode-module, which is composed of four cartridge-type electric tubes with Cs_2Te photocathodes. The photocathodes can be inserted into a single cell pillbox-type RF cavity. The maximum electric field strength on the photocathode surface, 90 MV/m, has been achieved for the pillbox-type cavity in only 2 h of RF processing following the exchange of the photocathode. The temporal behavior of the photocathode's quantum efficiency was measured following application of the electric field strength of 90 MV/m. The initial quantum efficiency of 3 % was halved to 1.5% in 5 h and finally settled to 1 % after 15 h. Analysis of the surface suggested the possibility of oxidization on the cathode surface rather than damage by vacuum discharges.
机译:该报告介绍了一种具有可更换Cs_2Te光电阴极的S波段光电注入器。该光电注入器配备有阴极模块,该阴极模块由带有Cs_2Te光电阴极的四个盒式电管组成。可以将光电阴极插入单细胞药盒型RF腔中。更换光电阴极后仅2小时的RF处理,药丸盒型腔在光电阴极表面上的最大电场强度为90 MV / m。在施加90 MV / m的电场强度后,测量了光电阴极量子效率的时间行为。 3%的初始量子效率在5小时内减半至1.5%,最后在15小时后降至1%。对表面的分析表明在阴极表面有氧化的可能性,而不是由真空放电造成的损坏。