首页> 外文期刊>Nuclear fusion >H mode discharges with feedback controlled radiative boundary in the ASDEX Upgrade tokamak
【24h】

H mode discharges with feedback controlled radiative boundary in the ASDEX Upgrade tokamak

机译:在ASDEX升级托卡马克中,H模式以受反馈控制的辐射边界放电

获取原文
获取原文并翻译 | 示例
       

摘要

Puffing of impurities (neon, argon) and deuterium gas in the main chamber is used to feedback control the total radiated power fraction and the divertor neutral particle density simultaneously in the ASDEX Upgrade tokamak. The variation of Psep=Pheat-Prad(core) by impurity radiation during H mode shows a similar effect on the ELM behaviour as that obtained by a change of the heating power. For radiated power fractions above 90%, the ELM amplitude becomes very small and detachment from the divertor plates occurs, whilst no degradation of the global energy confinement is observed (completely detached high confinement mode). Additional deuterium gas puffing is found to increase the radiated power per impurity ion in the plasma core owing to the combined effect of a higher particle recycling rate and a lower core penetration probability. The outer divertor chamber, which is closed for deuterium neutrals, builds up a high neutral pressure, the magnitude of which is determined by the balance of particle sources and pumping. For this particular situation, the effective pumping time of neon and argon is considerably reduced, to less than 0.3 s, mainly owing to an improved divertor retention capability. The radiation characteristics of discharges with a neon driven radiative mantle are modelled using a 1-D radial impurity transport code that has been coupled to a simple divertor model describing particle recycling and pumping. The results of simulations are in good agreement with experiment.
机译:在ASDEX升级托卡马克中,主腔室中的杂质(氖气,氩气)和氘气的抽吸可用于同时控制总辐射功率分数和偏滤器中性粒子密度。 H模式期间杂质辐射引起的Psep = Pheat-Prad(core)变化对ELM行为的影响与通过改变加热功率获得的影响相似。对于超过90%的辐射功率分数,ELM幅度变得非常小,并且发生从分流器板分离的现象,而没有观察到整体能量约束的退化(完全分离的高约束模式)。由于较高的颗粒回收率和较低的芯渗透率的综合作用,发现额外的氘气膨化会增加等离子体芯中每个杂质离子的辐射功率。外部分流器腔室对氘中性气体是封闭的,它会形成较高的中性压,其大小取决于颗粒源和泵送的平衡。对于这种特殊情况,氖和氩的有效泵送时间显着减少至少于0.3 s,这主要是由于改善了分流器保持能力。使用一维径向杂质传输代码对霓虹灯驱动的辐射罩的放电辐射特征进行建模,该代码已与描述颗粒回收和泵送的简单偏滤器模型耦合。仿真结果与实验吻合良好。

著录项

  • 来源
    《Nuclear fusion》 |1995年第10期|p. 1231-1246|共16页
  • 作者单位

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

    Max-Planck-Institut für Plasmaphysik, Euratom Association, Garching and Berlin, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 原子核物理学、高能物理学;
  • 关键词

  • 入库时间 2022-08-18 01:10:41

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号