首页> 外文期刊>Nuclear fusion >Measurement of the electron energy distribution function by a Langmuir probe in an ITER-like hydrogen negative ion source
【24h】

Measurement of the electron energy distribution function by a Langmuir probe in an ITER-like hydrogen negative ion source

机译:在类似ITER的氢负离子源中通过Langmuir探针测量电子能量分布函数

获取原文
获取原文并翻译 | 示例
           

摘要

Determining d(2)I/dV(2) from a traditional Langmuir probe trace using numerical techniques is inherently noisy and generally yields poor results. We have developed a Langmuir probe system based on a method first used in the 1950s by Boyd and Twiddy (1959 Proc. R. Soc. A 53 250). The system measures the 2nd derivative directly. This paper presents an account of the experimental method, apparatus and software used along with some preliminary results from the KAMABOKO III source including a comparison with conventional probe methods.
机译:使用数值技术从传统的Langmuir探针迹线确定d(2)I / dV(2)本质上是嘈杂的,并且通常会产生较差的结果。我们基于1950年代Boyd和Twiddy(1959 Proc。R. Soc。A 53250)首次使用的方法,开发了Langmuir探针系统。系统直接测量二阶导数。本文介绍了实验方法,设备和软件,以及KAMABOKO III来源的一些初步结果,包括与常规探针方法的比较。