Boron injection initiation temperature (BUT) provides important information for the safe shutdown of the reactor using boron injection system during anticipated transient without scram (ATWS). The purpose of this paper is to study BIIT curve of boiling water reactor owners' group (BWROG). The unreasonable and non-conservative parts of BIIT are pointed out and suggested modifications are made. The starting reactor power of BIIT is increased in order to meet the actual application. The lower limit of suppression pool temperature of BIIT is revised for conservative operation during ATWS conditions. Analysis of the effects of maximum temperature capacity of the suppression chamber and concentration of boron in standby liquid control tank shows that BIIT is decreased by adopting a more conservative value of maximum temperature capacity of the suppression chamber. Consequently, early boron injection is anticipated. For system with automatic boron injection system, BIIT is not required.
机译:硼注入起始温度(BUT)为重要的信息,可在预期的无扰动瞬变(ATWS)期间使用硼注入系统安全关闭反应堆。本文的目的是研究沸水反应堆所有者团体(BWROG)的BIIT曲线。指出了BIIT的不合理和非保守部分,并提出了建议的修改方案。增加BIIT的启动反应堆功率以满足实际应用。修改了BIIT抑制池温度的下限,以便在ATWS条件下进行保守操作。分析抑制室的最大温度容量和备用液体控制罐中的硼浓度的影响表明,采用更保守的抑制室的最大温度容量值可降低BIIT。因此,预计将尽早注入硼。对于具有自动硼喷射系统的系统,不需要BIIT。