Experimental study of the APR+ reactor core flow and pressure distributions under 4-pump running conditions

机译:四泵运行条件下APR +反应堆堆芯流量和压力分布的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

The core inlet flow rates and exit pressure distributions of an APR+ (Advanced Power Reactor Plus) reactor were evaluated experimentally with the ACOP (APR+ Core Flow & Pressure) test facility. The ACOP test facility was constructed with a linear reduced scale of 1/5 referring to the APR+ reactor. The major flow path from the clod leg to hot leg was preserved with a principle of similarity. The core region was simulated using 257 core simulators, which are representative of the real HIPER fuel assemblies that APR+ reactor adopted. The core inlet flow rates and pressure distributions along the main flow path, which are significant information as an input data to evaluate the core thermal margin and reactor safety, were obtained by differential pressures measured at core simulators representing 257 fuel assemblies, and the static or differential pressures at 584 points, respectively. Two kinds of experiments, 4-pump balanced and unbalanced flow conditions, were conducted to examine the hydraulic characteristics of the reactor coolant flow. The mass balance and overall pressure drop were carefully examined to check the reliability of the obtained values. The inlet flow rates of the two test results showed similar distributions, which met the hydraulic performance requirement. The details of these experiments, the facility, and a data analysis are also described in this paper.
机译:使用ACOP(APR +堆芯流量和压力)测试设备对APR +(先进动力堆Plus)反应堆的堆芯入口流速和出口压力分布进行了实验评估。相对于APR +反应器,ACOP测试设备的线性缩小比例为1/5。从凝块腿到热腿的主要流动路径得以保留,其原理相似。使用257个核心模拟器对核心区域进行了模拟,这是APR +反应堆采用的实际HIPER燃料组件的代表。通过在代表257个燃料组件的堆芯模拟器上测量的压差获得沿主要流道的堆芯入口流速和压力分布,这些信息是评估堆芯热裕度和反应堆安全性的重要输入数据,是重要信息。压差分别为584点。进行了两种实验,即4泵平衡和不平衡流动条件,以检查反应堆冷却剂流的水力特性。仔细检查质量平衡和总压降,以检查所获得值的可靠性。两种测试结果的入口流量显示相似的分布,满足水力性能要求。本文还介绍了这些实验的详细信息,设备和数据分析。

著录项

  • 来源
    《Nuclear Engineering and Design》 |2013年第12期|957-966|共10页
  • 作者单位

    Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Yuseong-Gu, Daejeon 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Yuseong-Gu, Daejeon 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Yuseong-Gu, Daejeon 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Yuseong-Gu, Daejeon 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Yuseong-Cu, Daejeon 305-353, Republic of Korea;

    Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Yuseong-Gu, Daejeon 305-353, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号