In-tube condensation of pure vapor are widely adopted by passive safety systems of advanced nuclear reactors to remove the decay heat. Accurate calculation of the in-tube condensation heat transfer coefficient is important for evaluating the heat removal ability. A better understanding of the mechanism of pure vapor condensation heat transfer and its modelling are essential for the design and assessment of those passive safety systems. An analytical model for pure vapor condensation in a vertical tube is developed based on mass, momentum and energy conservation equations. The total axial pressure drop is calculated through the momentum equation of the vapor core assuming a uniform radial pressure distribution. An optimized transition area between the laminar and turbulent film flow is defined to avoid discontinuity of heat transfer coefficients. Based on the sensitivity analyses, Kay's turbulent eddy diffusivity model and his turbulent Prandtl number model were recommended for the newly proposed model. The predicted results were compared with results of Shah (2016a, b), Chen et al. (1987) and Cavallini et al. (2002) correlations as well as Kuhn's and KAIST experimental data. It was found that the proposed model predicts the heat transfer coefficient well with a mean absolute deviation of 11.99% for Kuhn's data and 8.08% for KAIST's data. (C) 2017 Elsevier B.V. All rights reserved.
机译:先进核反应堆的被动安全系统广泛采用管内纯蒸汽冷凝来去除衰变热。管内冷凝传热系数的准确计算对于评估排热能力非常重要。更好地了解纯蒸汽冷凝传热的机理及其建模对于这些被动安全系统的设计和评估至关重要。基于质量,动量和能量守恒方程,建立了垂直管中纯蒸汽冷凝的分析模型。总轴向压降通过蒸气芯的动量方程式计算得出,假设径向压力分布均匀。定义了层流和湍流薄膜流之间的最佳过渡区域,以避免传热系数的不连续性。基于敏感性分析,建议将凯的湍流涡流扩散率模型和湍流的普朗特数模型用作新模型。将预测结果与Shah(2016a,b),Chen等人的结果进行了比较。 (1987)和Cavallini等。 (2002年)的相关性以及Kuhn和KAIST的实验数据。结果发现,提出的模型可以很好地预测传热系数,Kuhn数据的平均绝对偏差为11.99%,KAIST数据的平均绝对偏差为8.08%。 (C)2017 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Nuclear Engineering and Design》 |2017年第8期|346-360|共15页
  • 作者单位

    Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

    Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Analytical model; Pure vapor condensation; Vertical tube; Transition area; Heat transfer coefficient;