In this paper, the ex-core source-range detector response was simulated for AP1000 cores in its fuel-loading process by using a Monte Carlo code. Firstly, the current sensitivity coefficients of the ex-core source-range detectors have been calibrated by utilizing the experiments with single fuel assembly and the primary source loaded in the core. Secondly, both relative and absolute calibration methods have been applied and analyzed for the sensitivity coefficients calibration. Thirdly, the simulation values for the ex-core source-range response with fully loaded fuel have been validated by using the actual measurement of the first AP1000 cores in the world. Fourthly, the contribution of the U-238 spontaneous fission to the ex-core source-range detector response has been studied. Through the numerical simulation results, the following observations can be obtained: 1) The relative calibration method is better than the absolute calibration method, especially when the ex-core source-range response is small. 2) Compared with the measurements, the relative deviation between the simulated and the measured values is within 14% for the two AP1000 cores at Sanmen Nuclear Power Plant. 3) The intensity of U-238 spontaneous fission source accounts for 15% of the total source strength in the AP1000 core Unit 1, but the maximum change of response is only 0.02 cps, which is still insignificant for the ex-core detector response simulation in PWR.
机译:在本文中,通过使用蒙特卡洛代码在其燃料加载过程中为AP1000核模拟了前核来源范围探测器响应。首先,通过利用单燃料组件的实验和装入芯中的主要源来校准外芯源极程检测器的电流灵敏度系数。其次,已经施加和分析了相对校准方法,并分析了灵敏度系数校准。第三,通过使用世界上第一个AP1000核心的实际测量,已经通过了完全加载燃料进行了完全加载燃料的前核来源范围响应的模拟值。第四,已经研究了U-238自发性裂变对前核来源范围探测器响应的贡献。通过数值模拟结果,可以获得以下观察:1)相对校准方法优于绝对校准方法,特别是当前核源范围响应小时。 2)与测量相比,模拟和测量值之间的相对偏差在Sanmen核电站的两个AP1000核之间的14%范围内。 3)U-238自发裂变源的强度占AP1000核心单元1中总源强度的15%,但响应的最大变化仅为0.02 CPS,这对于前核检测器响应仿真仍然微不足道在pwr。

著录项

  • 来源
    《Nuclear Engineering and Design》 |2021年第2期|110995.1-110995.6|共6页
  • 作者单位

    Xi An Jiao Tong Univ Sch Nucl Sci & Technol Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Nucl Sci & Technol Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Nucl Sci & Technol Xian Shaanxi Peoples R China;

    Sanmen Nucl Power Co Ltd Taizhou Peoples R China;

    Xi An Jiao Tong Univ Sch Nucl Sci & Technol Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Nucl Sci & Technol Xian Shaanxi Peoples R China;

    Sanmen Nucl Power Co Ltd Taizhou Peoples R China;

    Xi An Jiao Tong Univ Sch Nucl Sci & Technol Xian Shaanxi Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    AP1000; Source-Range Detector response; Fuel-loading process;

    机译:AP1000;源区探测器响应;燃料加载过程;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号