A comparison between published analytical results with measured experimental results of the magnetic field produced by thermoelectric currents of subsurface semi-spherical pure tin inclusions embedded in a copper bar under the influence of an external heating and cooling into the specimen is presented. The measurements were taken from a 12.7 mm-thick copper bar with different subsurface semi-spherical pure tin inclusion diameters and lift-off distances between the sensor tip and specimen surface varied from 12.7 to 3.18 mm and from 1 to 8 mm, respectively. The experimental magnetic flux density measurements show a reasonable agreement as compared to analytical data as a function of the lift-off distances with the different inclusion diameters with the exception of the intrinsic material background magnetic signal that affected deeply the detectability of subtle imperfections in noncontacting thermoelectric measurements.
机译:提出的分析结果与在外部加热和冷却到试样中的,埋入铜条中的地下半球形纯锡夹杂物的热电流产生的磁场的测量实验结果进行比较。测量是从具有不同表面下半球形纯锡夹杂物直径的12.7 mm厚的铜条上进行的,传感器尖端与样品表面之间的剥离距离分别为12.7至3.18 mm和1至8 mm。实验性的磁通密度测量值与分析数据相比,具有不同夹杂物直径的剥离距离的函数显示出合理的一致性,但固有材料背景磁信号会深深影响非接触式热电中细微缺陷的可检测性测量。