首页> 外文期刊>NDT & E international >Fabrication of poly(vinylidene fluoride-trifluoroethylene) ultrasound focusing transducers and measurements of elastic constants of thin plates
【24h】

Fabrication of poly(vinylidene fluoride-trifluoroethylene) ultrasound focusing transducers and measurements of elastic constants of thin plates

机译:聚偏二氟乙烯-三氟乙烯超声聚焦换能器的制备及薄板弹性常数的测量

获取原文
获取原文并翻译 | 示例
       

摘要

This paper investigates a modified method for fabricating focusing ultrasound transducers based on spin-coated poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] copolymer films. The ferroelectric hysteresis loops of the spin-coated P(VDF-TrFE) films are measured to establish the best fabrication parameters. The fabricated transducers are used for high-frequency wave velocity measurements and for non-destructive determination of elastic constants of thin isotropic plates. Both through-thickness longitudinal wave velocities and Rayleigh surface wave velocities of thin-plate samples with thicknesses ranging from 125 to 250 μm are measured, and hence their elastic constants can be determined in a straightforward and accurate way. The obtained results are in good agreement with the data reported by the manufacturers. Limitation of the proposed fabrication method and conventional method is compared and discussed in terms of signal intensity and frequency characteristics.
机译:本文研究了一种基于旋涂聚偏二氟乙烯-三氟乙烯[P(VDF-TrFE)]共聚物薄膜的聚焦超声换能器的改进制造方法。测量旋涂P(VDF-TrFE)薄膜的铁电磁滞回线,以建立最佳制造参数。所制造的换能器用于高频波速测量和薄的各向同性板的弹性常数的无损确定。测量厚度范围为125至250μm的薄板样品的全厚度纵向波速和瑞利表面波速,因此可以以简单而准确的方式确定其弹性常数。获得的结果与制造商报告的数据高度吻合。从信号强度和频率特性方面比较和讨论了所提出的制造方法和传统方法的局限性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号