Purpose - In this paper, hybrid multienzyme biosensor system, which detects analyte through molecular conversion into signal response, is analyzed and presented. The biokinetic effects of pertinent parameters such as Michaelis-Menten constant, inhibitor inhibition and substrate inhibition modulus on biochemical reactions are investigated. Design/methodology/approach - Biochemical reaction models are described by five nonlinear equations for bisubstrate amperometric system analyzed adopting the regular perturbation method. Findings - Results obtained reveal that increasing Michaelis-Menten constant of oxygen causes a significant decrease in hydrogen peroxide concentration while increasing Michaelis-Menten constant of glucose shows increasing effect on oxygen concentration. Hence, results obtained from this work serve as reference for further analysis of concentration models and offer useful insight to relevant applications such as food safety, environmental and biomedical applications. Practical implications - This work serves as reference for further analysis of concentration models and offers useful insight to relevant applications such as food safety, environmental and biomedical applications. Originality/value - This paper examines the effect of biokinetic parameters on the concentration of the hybrid multienzyme biosensor. Here the effects of parameters such as inhibitor inhibition, substrate inhibition and Michealis-Menten were investigated on substrate, inhibition and product concentrations. It is illustrated from result that inhibitor parameter slows enzymatic catalytic reaction while substrate enhances reaction. This study applied approximate analytical scheme to investigate the biokinetic effects, adopting the regular perturbation scheme.
机译:目的 - 在本文中,分析并呈现通过分子转化为信号响应来检测分析物的杂化偏酶生物传感器系统。研究了迈克利斯 - 麦龄常数,抑制剂抑制和底物抑制模量的相关参数的杀菌效应。设计/方法/方法 - 生物化学反应模型由五个非线性方程描述了采用常规扰动方法的化学速率系统的五个非线性方程。结果 - 得到的结果表明,增加氧气的氧气常量导致过氧化氢浓度显着降低,同时增加葡萄糖的迈克利斯 - 肉体常数显示出对氧浓度的影响。因此,从该工作获得的结果有助于进一步分析集中模型,并对食品安全,环境和生物医学应用等相关应用提供有用的见解。实际意义 - 这项工作是参考浓度模型的进一步分析,并提供对食品安全,环境和生物医学应用等相关应用的有用见解。原创性/值 - 本文研究了杀虫参数对杂交偏髓生物传感器浓度的影响。这里研究了抑制剂抑制,底物抑制和MICHEALIS-MENTen的参数的影响,对基材,抑制和产物浓度进行了研究。从抑制剂参数加剧酶促催化反应的结果,同时碱性增强反应。该研究应用了近似分析方案来研究常规扰动方案的杀虫效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号