首页> 外文期刊>Microchimica Acta >A Simple and Straightforward Procedure for Monitoring Phenol Compounds in Waters by Using UV Solid Phase Transduction Integrated in a Continuous Flow System
【24h】

A Simple and Straightforward Procedure for Monitoring Phenol Compounds in Waters by Using UV Solid Phase Transduction Integrated in a Continuous Flow System

机译:使用集成在连续流系统中的UV固相转导监测水体中酚类化合物的简单而直接的程序

获取原文
获取原文并翻译 | 示例
           

摘要

A novel and sensitive flow-through method with solid phase UV spectrophotometric transduction is proposed for the direct determination of phenols: phenol, 1-naphthol, 2-naphthol, 3,4-dimethylphenol and 2,4-dichlorophenol were used as test phenol compounds. The device consists of a monochannel system using Sephadex QAE A-25 resin as packing material of the detection microzone placed inside a flow-through cell on which phenols are temporarily retained. Intrinsic absorbances are monitored at 237 nm for phenol, 242 nm for 2-naphthol and 3,4-dimethylphenol, and 247 nm for 1-naphthol and 2,4-dichlorophenol. The sample is transported by a alkaline carrier solution which acts as desorbing the solution itself. The determination of phenols was carried out for 40 and 600 µL of sample volume. The sensitivity is higher by a factor of 10 than that provided by a conventional flow injection analysis method. The detection limits were found to be close to 1 ng mL−1 in some cases (using 600 µL of sample volume). The relative standard deviations (n=10) ranged between 1.5 and 3.2% (40 µL) and 1.1 and 2.2% (600 µL). The proposed method has shown good results in its application to waters, making this method suitable for phenol monitoring.
机译:提出了一种新的灵敏的固相紫外分光光度法直接测定苯酚的方法:使用苯酚,1-萘酚,2-萘酚,3,4-二甲基苯酚和2,4-二氯苯酚作为测试酚类化合物。 。该设备由单通道系统组成,该系统使用Sephadex QAE A-25树脂作为检测微区的填充材料,该检测微区放置在流通池内部,苯酚暂时保留在流通池中。苯酚固有吸光度在237 nm处监测,2-萘酚和3,4-二甲基苯酚在242 nm处监测,1-萘酚和2,4-二氯苯酚在247 nm处监测。样品由碱性载体溶液运输,该溶液本身使溶液解吸。苯酚的测定是针对40和600 µL的样品量进行的。灵敏度比常规流动注射分析方法提供的灵敏度高10倍。在某些情况下(使用600 µL样品体积),检测限接近1 ng mL-1 。相对标准偏差(n = 10)在1.5和3.2%(40 µL)到1.1和2.2%(600 µL)之间。所提出的方法在水中应用中显示出良好的效果,使该方法适用于苯酚监测。

著录项

  • 来源
    《Microchimica Acta》 |2003年第4期|143-148|共6页
  • 作者单位

    Department of Physical and Analytical Chemistry Faculty of Experimental Sciences University of Jaén Jaén Spain;

    Department of Physical and Analytical Chemistry Faculty of Experimental Sciences University of Jaén Jaén Spain;

    Department of Physical and Analytical Chemistry Faculty of Experimental Sciences University of Jaén Jaén Spain;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Key words: Flow-through detector; spectrophotometry; phenols; waters.;