Platinum in coke samples was determined by inductively coupled plasma mass spectrometry (ICP-MS) after microwave-assisted sample digestion and temperature controlled microwave assisted cloud point extraction (MW-CPE). Interferences due to hafnium (179Hf16O) were successfully eliminated using MW-CPE with 2-MBT prior to the determination of platinum by ICP-MS. The validity of the method was studied by spike recovery tests and by analyzing certified reference material (BCR-723 street dust). The results obtained for platinum in the BCR-723 were generally in good agreement with the certified values. Furthermore, the preliminary platinum results obtained for coke sample by ICP-MS after MW-CPE were compared to those obtained by a reference method (NiS-Fire Assay preconcentration/Te coprecipitation and ICP-MS determination). Keywords Coke - Platinum - Cloud point extraction - Inductively coupled plasma mass spectrometry (ICP-MS)
机译:微波辅助样品消化和温度控制的微波辅助浊点萃取(MW-CPE)后,通过电感耦合等离子体质谱法(ICP-MS)测定焦炭样品中的铂。使用MW-CPE和2-MBT可以成功消除ha( 179 Hf 16 O)引起的干扰,然后通过ICP-MS测定铂。通过加标回收率测试和通过分析认证的参考材料(BCR-723街道粉尘)研究了该方法的有效性。 BCR-723中铂的测定结果与认证值基本吻合。此外,将MW-CPE后通过ICP-MS获得的焦炭样品初步铂金结果与通过参考方法获得的初步铂金结果进行了比较(NiS-Fire Assay预浓缩/ Te共沉淀和ICP-MS测定)。关键词焦炭-铂-浊点萃取-电感耦合等离子体质谱(ICP-MS)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号