首页> 外文期刊>Metallurgical and Materials Transactions A >Effect of specimen geometry, gage length, and width measurement locations on plastic strain ratio (R-value) in sheet metals
【24h】

Effect of specimen geometry, gage length, and width measurement locations on plastic strain ratio (R-value) in sheet metals

机译:样品几何形状,量规长度和宽度测量位置对钣金件塑性应变比(R值)的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The effects of gage length, width measurement locations, and specimen geometry on plastic strain ratio have been investigated for the AA8011 aluminum alloy and interstitial-free (IF) steel sheets. The specimens were ASTM E 517 to 92a subsize, type A, and type A alternative with, respectively, 37.5, 76, and 57 mm reduced parallel sections and with different fillet radii. In each specimen type, there were differences in axial strains of gage marks and changes in width strain over the reduced parallel section, which depend on the applied axial strain, reduced parallel section legth, and fillet radius. Therefore, the magnitudes of the calculated R-values depend upon gage length, width measurement location, axial strain, and specimen geometry. These dependencies were more pronounced in the high R-value IF steel sheet relative to the low R-value AA8011 aluminum alloy sheet. The dependencies of R-value on gage length and width measurement location are negligible in all AA8011 specimens, while in IF specimens, these dependencies can be neglected only for type A specimens with 12.5-mm fillet radius. It is concluded that the observed differences in the measured R-values for specimens with different geometries can be attributed to the constraints imposed by the shoulders, which affect the width strain measurements and the resulting R-values.
机译:对于AA8011铝合金和无间隙(IF)钢板,已经研究了量规长度,宽度测量位置和试样几何形状对塑性应变比的影响。样品分别为ASTM E 517至92a亚型,A型和A型替代品,分别具有37.5、76和57 mm的减小的平行截面和不同的圆角半径。在每种类型的样品中,规规标记的轴向应变和减小的平行截面上宽度应变的变化都存在差异,这取决于所施加的轴向应变,减小的平行截面长度和圆角半径。因此,计算出的R值的大小取决于量规的长度,宽度测量位置,轴向应变和试样的几何形状。这些相关性在高R值IF钢板中相对于低R值AA8011铝合金板更为明显。在所有AA8011样品中,R值对量具长度和宽度测量位置的依赖性都可以忽略,而在IF样品中,这些依赖性仅对于圆角半径为12.5 mm的A型样品可以忽略。结论是,对于具有不同几何形状的样品,在测量的R值中观察到的差异可以归因于肩部施加的约束,这会影响宽度应变测量和所得的R值。

著录项

  • 来源
    《Metallurgical and Materials Transactions A》 |2006年第12期|3477-3487|共11页
  • 作者

    A. Chamanfar; R. Mahmudi;

  • 作者单位

    Department of Metallurgical and Materials Engineering Faculty of Engineering University of Tehran Tehran Iran;

    Department of Metallurgical and Materials Engineering Faculty of Engineering University of Tehran Tehran Iran;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号