首页> 外文期刊>Metal finishing >Troubleshooting Salt Spray Failures
【24h】

Troubleshooting Salt Spray Failures

机译:故障排除盐雾故障

获取原文
获取原文并翻译 | 示例
           

摘要

Anodize salt spray (SS) failures are infrequent due to the robust BSAA (Boric Acid-Sulfuric Acid Anodizing) process. However, when failures do occur the problem is rather frustrating due to the numerous possible causes. The Anodize Troubleshooting Guide (ATG) is useful as a checklist to systematically isolate areas for further investigation. Boeing has used this technique on several occasions and the result has been faster decisions for taking immediate corrective action and successful resolution of the anodize SS failure problem at hand.
机译:由于健壮的BSAA(硼酸-硫酸阳极氧化)工艺,阳极氧化盐雾(SS)的故障很少发生。但是,当确实发生故障时,由于许多可能的原因,问题相当令人沮丧。 《阳极氧化故障排除指南》(ATG)可用作检查清单,可以系统地隔离区域以进行进一步调查。波音公司已经在多种场合使用了该技术,其结果是可以更快地做出决定,以便立即采取纠正措施并成功解决眼前的阳极氧化SS故障问题。