Location of small gastric or colorectal tumors during a laparoscopic procedure is often imprecise and can be misleading. There is a real need for a compatible and straightforward tool that can be used intraoperatively to help the surgeon in this regard. We emphasize in the present work on the fabrication of a new and innovative inductive proximity switch architecture, fully compatible with laparoscopic surgery and with direct application in precise localisation of bowel tumors. An electromagnetic detection probe optimized for laparoscopic surgery and preconditioned for sterilisation was designed and constructed. Various metallic markers designed to be attached to the gastrointestinal mucosa were used for detection by the probe, from standard endoscopic and laparoscopic haemostatic clips to other custom made tags. Experiments were performed in dry and wet-lab experimental laboratory environment using ex-vivo segments of calfs small bowel and colonic surgical specimens from human patients. The dry-lab detection range varied considerably depending on the metallic component of the tags, from 0.5 mm for the endoscopic hemostatic clip to 3.5 mm for the 0.9 mm thickness stainless-steel custom tags. The latter was actually detectable from the serosal side of the fresh colonic surgical specimens in 85% of the attempts if the scanned area was less than 150 cm(2) and less than 2 min of fat was interposed between the probe and the bowel. The newly designed system has the potential to discover metallic tags attached to the bowel mucosa for precise intraoperative laparoscopic location of digestive tumors. Further work is in progress to increase the sensitivity and detection range of the system in order to make it fully compatible with the clinical use.
机译:腹腔镜手术期间胃或结肠直肠小肿瘤的定位通常不准确,可能会产生误导。真正需要可在手术中用于在这方面帮助外科医生的兼容且直接的工具。在当前工作中,我们强调制造一种新颖的,创新的感应式接近开关架构,该架构与腹腔镜手术完全兼容,并直接应用于肠道肿瘤的精确定位。设计并构造了一种针对腹腔镜手术进行了优化并经过灭菌预处理的电磁检测探头。从标准的内窥镜和腹腔镜止血夹到其他定制的标签,各种设计用来附着在胃肠道粘膜上的金属标记物都可以通过探针进行检测。实验是在小实验室和干实验室实验室环境中进行的,使用了小腿小肠和来自人类患者的结肠外科手术标本的离体片段。干燥实验室的检测范围取决于标签的金属成分,从内窥镜止血夹的0.5毫米到厚度为0.9毫米的不锈钢定制标签的3.5毫米不等。如果扫描区域小于150 cm(2)且探针和肠之间插入的脂肪少于2分钟,则实际上可以从新鲜结肠外科手术标本的浆膜侧检测到后者,其尝试率为85%。新设计的系统有可能发现附着在肠粘膜上的金属标签,从而在腹腔镜下精确定位消化道肿瘤。为了使系统与临床用途完全兼容,正在进行进一步的工作以增加系统的灵敏度和检测范围。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号