Biocompatibility and degradation behaviour of degradable magnesium sponges coated with bioglass - method establishment within the framework of a pilot study

机译:涂有生物玻璃的可降解镁海绵的生物相容性和降解行为-在试点研究框架内建立方法

获取原文
获取原文并翻译 | 示例
           

摘要

Ziel dieser Studie war die Methodenetablierung zur Untersuchung von Biokompatibilität und Degradationsverhalten von Magnesiumschwämmen mit Beschichtung in spongiösem Knochen. Es wurden bioglasbeschichtete Schwämme der Magnesiumlegierung AX30 für 6,12 oder 24 Wochen in Kaninchenfemora implantiert. Es folgten regelmäßige klinische und radiologische Untersuchungen, in vivo (XtremeCT) und ex vivo (μCTSO) μ-Computertomographien und histologische Untersuchungen. Der Trochanter major erwies sich als geeigneter Implantationsort und die beschichteten Magnesiumschwämme als gut verträglich. Die Röntgenaufnahmen zeigten weder Gasentwicklung noch gravierende Knochenveränderungen. Das XtremeCT stellte Degradationsfortschritte und Gas dar, stellte sich aber als wenig aussagekräftig bezüglich der exakten Bestimmung der Umbauvorgänge von Implantat und Knochen heraus. Bessere Ergebnisse bezüglich des Degradationsfortschritts der Schwämme lieferte hingegen das μCT80 am Versuchsende. Nach allen Implantationszeiten wurden unterschiedlich große Schwammresiduen und neu gebildeter Knochen nachgewiesen. Die histologischen Untersuchungen ergaben neben der Knochenneubildung milde, abnehmende Entzündungsreaktionen. Die Knochen-Implantat-Grenzflächen konnten nicht an allen Lokalisationen untersucht werden, da sich das Implantatmaterial während des Schneidevorgangs am Mikrotom z.T. herauslöste. Insgesamt eignen sich die gewählten Methoden für die Verwendung in weiteren Studien. Zusätzlich ist jedoch die Einführung der Trenn-Dünn-schliff-Methode nach Donath zur Untersuchung des Implantat-Knochen-Verbundes wichtig.%Aim of the present study was to establish methods for the evaluation of biocompatibility and degradation behaviour of coated magnesium sponges in cancellous bone. So bioglass coated sponges of the magnesium alloy AX30 were implanted into the femurs of rabbits for an observation period of 6, 12 and 24 weeks, respectively. In the follow up clinical and radiographical examinations and in vivo μ-computed tomographies (XtremeCT) were taken regularly. After euthanasia ex vivo μ-computed tomographies (μCTSO) and histological examinations were executed. As result the greater trochanter proved to be a suitable implantation site and all coated magnesium sponges were tolerated well. The radiographs showed no development of gas or severe bone alterations. The XtremeCT depicted the proceeding degradation and accumulations of gas, but turned out to be not as meaningful in exact determination of bone and sponge changes. Better results regarding the degradation state of the sponges were provided by the μCT80 at the end of the test. After all implantation periods different sized implant residues and newly formed bone around the implant were found. The histological examinations resulted in new bone formation and a mild, decreasing inflammation. The bone-implant-interface could not be evaluated at all localisations, since the remaining implants partly coiled up during microtome sectioning. In conclusion the chosen methods are suitable for usage in further studies. But supplement of the cutting and grinding method according to Donath is required to examine the bone-implant-compound.
机译:这项研究的目的是建立一种方法来研究涂有松质骨的海绵镁的生物相容性和降解行为。将AX30镁合金的生物玻璃涂层海绵植入兔股骨中6、12或24周。随后进行常规临床和放射学检查,体内(XtremeCT)和离体(μCTSO)μ电脑断层扫描和组织学检查。更大的转子被证明是合适的植入部位,并且涂覆的镁海绵具有良好的耐受性。 X射线检查既未显示出气体生成,也未显示严重的骨骼变化。 XtremeCT表现出降解的进展和气体,但是对于准确确定植入物和骨骼的转化过程而言却没有太大意义。然而,在测试结束时,μCT80在海绵的降解进程方面提供了更好的结果。在所有植入时间之后,检测到大小不同的海绵残留物和新形成的骨头。除了新的骨形成,组织学检查还显示出轻度,减少的炎症反应。由于在切割过程中植入物材料部分粘在切片机上,因此无法在所有位置都检查骨植入物界面。已发布。总体而言,选择的方法适用于进一步的研究。此外,引入Donath分离薄层法来检查植入物与骨之间的结合也很重要。%本研究的目的是建立一种方法,用于评价包被的镁海绵在松质骨中的生物相容性和降解行为。因此,将镁合金AX30的生物玻璃涂层海绵植入兔股骨,观察期分别为6、12和24周。在随访中,定期进行临床和放射照相检查以及体内μ计算机断层扫描(XtremeCT)。安乐死后进行体外μ计算机断层扫描(μCTSO)和组织学检查。结果,较大的转子被证明是合适的植入部位,并且所有涂覆的镁海绵都被很好地耐受。放射线照片未显示出气体或严重的骨骼改变。 XtremeCT描绘了气体的逐步降解和积累,但结果证明对准确确定骨骼和海绵的变化没有意义。在测试结束时,μCT80提供了有关海绵降解状态的更好结果。在所有植入期后,发现大小不同的植入物残留物和植入物周围新形成的骨头。组织学检查导致新的骨形成和轻度减轻的炎症。骨-植入物界面无法在所有位置上进行评估,因为其余的植入物在切片机切片过程中部分卷曲。总之,所选方法适合于进一步研究。但是,根据Donath的要求,需要补充切割和研磨方法,以检查骨植入物化合物。

著录项

  • 来源
    《Materialwissenschaft und Werkstofftechnik》 |2010年第12期|p.1025-1034|共10页
  • 作者单位

    Small Animal clinic, University of Veterinary Medicine Hannover, Hannover,Small Animal Clinic, University of Veterinary Medicine Hannover, 30559 Hannover;

    Small Animal clinic, University of Veterinary Medicine Hannover, Hannover;

    Small Animal clinic, University of Veterinary Medicine Hannover, Hannover;

    Institute of Materials Science, Leibniz University Hannover, Garbsen;

    Small Animal clinic, University of Veterinary Medicine Hannover, Hannover;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    sponge; bioglass coating; in vivo; magnesium alloy; resorbable;

    机译:海绵;生物玻璃涂层;体内;镁合金可吸收的;