首页> 外文期刊>Marine Structures >Bond-slip behaviour of concrete filled double skin steel tubular (CFDST) columns
【24h】

Bond-slip behaviour of concrete filled double skin steel tubular (CFDST) columns

机译:混凝土填充双层钢管(CFDST)柱的粘结滑动行为

获取原文
获取原文并翻译 | 示例
       

摘要

This paper provides novel results and key findings for the bond-slip field since there is no single study available in the literature conducted on the bond-slip behaviour of concrete filled double skin steel tubular (CFDST) columns. Likewise, no studies have been focused on the contribution of welded reinforcing bars on the bond behaviour of composite columns. A series of push-out tests on sixteen specimens of CFDST columns are presented to explore the bond-slip behaviour between the cross-sectional elements (the inner steel tube, outer steel tube and the shell concrete). The primary test parameters involve (a) interface type (normal interface, interface with an internal ring, with reinforcing bars, and with shear studs); (b) concrete strength (high strength concrete and normal strength concrete); (c) push-out type (push-out of the shell concrete and push-out of the inner tube). The results demonstrated that greater benefits arose on the bond strength, once the reinforcing bars or internal rings were welded onto the inner steel tube of CFDST columns. Moreover, in addition to remarkably improving the bond strength, the welded reinforcement bars would significantly improve the compressive strength of CFDST columns and eliminate the local buckling of the inner steel tube. On the other hand, the embedded shear studs (bolts) onto inner steel tubes are capable of improving the bond strength with less degree of the shear resistance in comparison with the other interface types. What's more, the current paper is also adapted to explore the influence of concrete grade (normal and high strength) on the bond performance of CFDST columns and it is showed that the bond strength increases considerably as the strength of the shell concrete is increased. Finally, the bond improvement ratio (BIR) is studied which could be a representative index in comparing the performances of the parameters on the bond behaviour.
机译:本文提供了新的措施和粘结性领域的主要研究结果,因为在填充双层钢管(CFDST)柱的粘结性行为上没有任何一项研究。同样,没有研究焊接加强杆对复合柱键合行为的贡献。提出了一系列关于CFDST柱标本的一系列推出测试,探讨了横截面元件(内钢管,外钢管和壳体混凝土)之间的粘合性净化行为。主要测试参数涉及(a)界面类型(正常接口,带内环的接口,带钢杆和剪切螺柱); (b)混凝土强度(高强度混凝土和正常强度混凝土); (c)推出型(推出壳体混凝土,推出内管)。结果表明,一旦将加强杆或内圈焊接到CFDST柱的内钢管上,就会产生更大的益处。此外,除了显着提高粘合强度之外,焊接加强杆将显着提高CFDST柱的抗压强度,并消除内钢管的局部屈曲。另一方面,与其他界面类型相比,内钢管上的嵌入式剪切螺柱(螺栓)能够改善具有较少程度的剪切电阻的粘合强度。更重要的是,目前的论文还适用于探讨混凝土级(正常和高强度)对CFDST柱的粘合性能的影响,结果表明,随着壳体混凝土的强度增加,粘合强度显着增加。最后,研究了键改性率(BIR),其可以是比较键合行为上参数的性能的代表性指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号