On 16th Feb 2012, the captioned vessel observed water overflowing from the CCFW expansion tank in bursts. The vessel was slowed down and stopped, but due to a large amount of air in the water system, two diesel generators tripped. The standby diesel generators started, but they also tripped on high jacket water temperature. Subsequently, the emergency generator started and the vessel was on emergency power. The overflowing ceased after some time and the level of the expansion tank dropped below the sight glass. No abnormality was observed on the diesel generators and main engine.
机译:在2012年2月16日,带字幕的船只观察到CCFW膨胀水箱中突然涌出水。该船减速并停下,但由于水系统中有大量空气,导致两台柴油发电机跳闸。备用柴油发电机启动了,但由于水套水温高而跳闸。随后,应急发电机启动,船只处于应急状态。过了一段时间,溢流停止了,膨胀水箱的水位降到了观察孔以下。在柴油发电机和主机上未发现异常。